1 рассчитан на мощность в…
- designed for capacity of...
рассчитан на мощность в…
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
EN
- designed for capacity of...
Русско-английский словарь нормативно-технической терминологии > рассчитан на мощность в…
-
2 коэффициент
coefficient (coeff.), factor
безразмерное число, в основном отношение к-п. величин, характеризующих заданные условия. — а number indicating the amount of some change under certain specified сoпditions, often expressed as a ratio.
- безопасности — factor of safety
число, равное отношению расчетной нагрузки к эксплуатационной. расчетная нагрузка - произведение эксплуатационной нагрузки на коэффициент безопасности. — а number indicating the ratio between the ultimate load and limit load (maximum load expected in service). ultimate load is limit load multiplied by factor of safety.
- восстановления давления — pressure recovery factor
- двухконтурности (дтрд) — bypass ratio
- загрузки пассажирами, безубыточный — passenger break-even load factor
- запаса длины впп — field length factor
- запаса длины летной полосы — field length factor
- запаса длины летной полосы в направлении взлета — takeoff field length factor
- запаса длины летной полосы в направлении посадки — landing field length factor
- запаса длины летной полосы при всех работающих двигателей — field length factor for all-engines-operating сase
- запаса длины летной полосы при одном отказавшем двигателе — field length factor for one-engine-inoperative ease
- запаса прочности — reserve factor
отношение фактической прочности конструкции к минимально-потребной в данных условиях. — а ratio of the actual strength of the structure to the minimum required to specific condition.
- заполнения (в вычислительном уст-ве) — duty factor in computer, the ratio of active time to total time.
- заполнения (воздушного) винта — propeller solidity ratio
отношение суммарной площади всех лопастей винта к сметаемой ими площади. — the ratio of the total projected blade area to the area of the projected outline of the propeller disc.
- заполнения несущего винта (вертолета) — rotor solidity ratio solidity of rotor is a ratio of the total blade area to the disc area.
- лобового сопротивления (сх) — drag coefficient (cd)
коэффициент, характеризующий лобовое сопротивление рассматриваемого аэродинамического профиля. — а coefficient representing the drag on а given airfoil.
- маневренной перегрузки — maneuvering load factor
- момента крена — rolling-moment coefficient
- момента рыскания — yawing-moment coefficient
- момента тангажа — pitching-moment coefficient
- мощности — power factor
- мощности (воздушного винта) — activity factor
- мощности лопасти (возд. винта) — blade activity factor
безразмерная функция поверхности лопасти, характеризующая способность лопасти использовать прикладываемую мощность. — а non-dimensional function of the blade surface used to express capacity of a blade for absorbing power.
- несущей поверхности (покрытия аэродрома), калифорнийский — californian bearing ratio (с.в.r.)
-, относительный (воздушного винта) — figure of merit
- перегрузки (n) — load factor (n)
число, показывающее, во сколько раз нагрузки, действующие на самолет (или его отдельные части), превышает нагрузки в равномерном горизонтальном полете или нагрузки от веса при стоянке. — the ratio to the weight of an aircraft of а specified exterпаl load. such load may arise from aerodynamic forces, gravity, ground or water reaction, or from combinations of these forces.
- перегрузки, максимальный эксплуатационный — limit load factor
- перегрузки, (полетный) — flight load factor
отношение составляющей аэродинамической нагрузки (действующей перпендикулярно продольной оси ла) к весу ла. — the ratio of the aerodynamic force component (acting normal to the assumed longitudiпа1 axis of the airplane) to the weight of the airplane.
- перегрузки (полетной), отрицательный — negative load factor
- перегрузки (полетной), положительный — positive load factor
в данном случае аэродинамичеекая сила воздействует на ла снизу вверх. — in positive load factor the aerodynamic force acts upward with respect to the airplane.
- перегрузки при маневре — maneuvering load factor
- перегрузки при маневре, максимальный эксплуатационный — limit maneuvering load factor
- перегрузки, расчетный — ultimate load factor
- передачи (коэффициент передаточного числа в системе управления ла) — gain
- подъемной силы (су) безразмерная величина, определяемая по формуле. — lift coefficient (cl) а coefficient representing the lift of а given airfoil or other body. the lift coefficient is obtained ьу dividing the lift by the free-stream dynamic pressure and by the representative area under consideration.
- полезного действия (кпд) — efficiency (n)
the ratio of the useful output of the quantity to its total input.
- полезного действия, общий — overall efficiency
- полезного действия,тепловой — thermal efficiency
-, поправочный — correction factor
например, для учета влияния погодных (сезонных) условий (температура наружного воздуха, атмосферные осадки, обледенение) на характеристики тормозного участка впп в пределах установленных эксплуатационных ограничений. — the correction factors must account for the particular surface characteristics of the stopway and the variations in these characteristics with seasonal weather conditions (such as temperature, rain, snow, and ice) within the established operational limits.
- предельной перегрузки — ultimate load factor
- преобразования (в преобразователе) — conversion efficiency ratio of dc output power to ас input power.
- профильного сопротивления — profile drag coefficient
- прочности грунта, калифорнийский — californian bearing ratio (c.b.r.)
(к. несущей способности покрытия аэродрома, впп) — c.b.r. is used to measure subsoil strength of the runways and airfields.
- связи (эл.) — coupling coefficient
- сжимаемости — coefficient of compressibility
относительное уменьшение объема газа при повышении давления в изотермическом процессе. — the relative decrease of the volume of а gaseous system with increasing pressure in an isothermal process.
- совершенства (воздушного винта) — figure of merit
- сопротивления (лобовой, сx) — drag coefficient (cd)
- сопротивления (сx) груза на внешней подвеске (вертолета) — drag coefficient (cd) representing а drag caused by an externally-slung load
- стоячей волны — standing wave ratio (swr)
- схождения карты — chart convergence factor (ccf)
- сцепления (между шиной колеса и поверхностью впп) — coefficient of friction
-, сцепления (между шиной и впп при торможении) — braking coefficient of friction
- трансформации (в трансформаторе) — transformation ratio compensation windings are used to correct for variations in the resolvers transformation ratio.
- трения — coefficient of friction
- трения торможения — braking coefficient of friction
коэффициент трения между шиной и поверхностью взлетно-посадочной полосы при торможении самолета. — braking coefficient of friction between the aircraft wheel tires and runway (surface).
- трения торможения, осредненный приведенный — (mean) corrected braking coefficient of friction
- тяги (воздушного винта) — thrust coefficient (ст)
- усиления (эл.) — amplification factor
the ratio of output magnitude to input magnitude.
- усиления антенны — antenna gain
- усиления (передаточное число в системе управления) — gain
- усиления, самонастраивающийся (системы управления) — adaptive gain
- утечки — leakage factor
- шарнирного момента — hinge moment factor
- шарнирного момента от порыва ветра на земле, предельный — limit hinge moment factor (к) for ground gusts
в отношении элеронов и рулей высоты, коэффициент имеет положительный знак, если момент, воздействующий на поверхность управления, вызывает ее опускание. — for ailerons and elevators, а positive value of к indicates а moment tending to depress the surface, and а negative value of к - to raise the surface.
- шума — noise factor
для данной полосы частот, отношение суммарной величины помех на выходе к величине помехи на входе. — for а given bandwidth, the ratio оf total noise at the output, to the noise at the input.
- эксплуатационной маневренной перегрузки (максимальный), или эксплуатационной перегрузки при маневрировании (отрицательный или попожительный) — (negative, positive) limit maneuvering load factor rotorcraft must be designed for positive limit maneuvering load factor of 3.5 and negafive limit maneuvering load factor of 1.0.Русско-английский сборник авиационно-технических терминов > коэффициент
-
3 проходимость,
rough-field capacity
высокая (самолета, т.е. способность эксплуатироваться с неподготовленных аэродромов) — the airplane is designed for rough field operation.Русско-английский сборник авиационно-технических терминов > проходимость,
-
4 параллельная система ИБП
параллельная система ИБП
-
[Интент]Parallel Operation: The system shall have the option to install up to four (4) UPSs in parallel configuration for redundancy or capacity.
1. The parallel UPS system shall be of the same design, voltage, and frequency. UPS modules of different size ratings shall be permitted to be paralleled together for purposes of increased capacity or UPS module redundancy. The UPSs in the parallel configuration shall not be required to have the same load capacity rating.
2. Parallel Capacity: With N+0 system-level redundancy, up to 2MW of load can be supported by the system.
3. Parallel Redundancy: With N+1 system-level redundancy, up to 1.5MW of load can be supported by the system, and only the UPS being replaced must be isolated from the source (bypass operation is not required for the entire system during the UPS replacement procedure).
4. Output control: A load sharing circuit shall be incorporated into the parallel control circuits to ensure that under no-load conditions, no circulating current exists between modules. This feature also allows each UPS to share equal amounts of the total critical load bus. The output voltage, output frequency, output phase angle, and output impedance of each module shall operate in uniformity to ensure correct load sharing. This control function shall not require any additional footprint and shall be an integral function of each UPS. The static bypass switches shall be connected in parallel.
5. Parallel System Controls: To avoid single points of failure, the UPS system shall have no single dedicated control system designed to control the operation of the parallel UPS system. Control of and direction of parallel UPSs shall take place via a master/slave relationship, where the first UPS to receive logic power asserts itself as a master. In the event of a master failure, a slave UPS shall take the role of master and assume the responsibility of the previous master UPS. Regardless of which UPS is master or slave, user changes to the system status, such as request for bypass, can be done from any UPS connected to the bus and all UPS on the bus shall transfer in simultaneously.
6. Communication: Communication between modules shall be connected so that the removal of any single cable shall not jeopardize the integrity of the parallel communication system. Load sharing communications shall be galvanically isolated for purposes of fault tolerance between UPS modules. A UPS module's influence over load sharing shall be inhibited in any mode where the UPS inverter is not supporting its output bus. Transfers to and from bypass can be initiated from any online UPS in the system.
7. Display: Each UPS multi-color LCD touch screen user interface shall be capable of using an active touch screen mimic bus to show the quantity of UPS(s) connected to the critical bus, as well as the general status of each UPS, such as circuit breaker status information. Any touchscreen display shall support the configuration of the [entire parallel] system and shall provide event and alarm data for all UPSs in the parallel configuration. A Virtual Display Application shall be available for download to the customer’s computer and shalll support remote monitoring of a complete system with up to 4 UPSs in parallel.
8. Battery runtime: Each UPS must have its own battery solution. The battery solution for the entire system can be a combination of standard and third-party batteries, but each UPS must use only one battery solution – either standard or third-party batteries.
9. Switchgear: A custom switchgear option shall be required for parallel operation.
[Schneider Electric]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > параллельная система ИБП
-
5 номинальная способность к присоединению
номинальная способность к присоединению
Диапазон и/или число номинальных сечений проводников, на которое рассчитана клемма
[ ГОСТ Р 50030.7.1-2000]EN
rated connecting capacity
range of cross-sections and, if applicable, the number of connectable conductors, for which the terminal block is designed
[IEC 60947-7-1, ed. 3.0 (2009-04)]
rated connecting capacity
cross-sectional area of the largest conductor(s) to be connected as stated by the manufacturer of the installation couple
[IEC 61535, ed. 1.0 (2009-02)]
rated connecting capacity
cross-sectional area of the largest conductors as declared by the manufacturer
[IEC 60670-22, ed. 1.0 (2003-05)]
rated connecting capacity
cross-sectional area of the largest rigid conductor(s) to be connected as stated by the manufacturer of the connecting device. In the case of a connecting device for flexible conductors only, the rated connecting capacity is the cross-sectional area of the largest flexible conductor to be connected
[IEC 60998-1, ed. 2.0 (2002-12)]FR
capacité assignée de raccordement
gamme de sections et, le cas échéant, nombre de conducteurs raccordables, pour lesquels le bloc de jonction est conçu
[IEC 60947-7-1, ed. 3.0 (2009-04)]
capacité assignée de connexion
section du ou des plus grands conducteurs susceptibles d’être connectés comme indiqué par le fabricant du coupleur d’installation
[IEC 61535, ed. 1.0 (2009-02)]
capacité assignée de connexion
section du ou des plus gros conducteurs déclarée par le constructeur
[IEC 60670-22, ed. 1.0 (2003-05)]
capacité de connexion assignée
section du ou des plus gros conducteurs rigides à raccorder, déclarée par le constructeur du dispositif de connexion. Dans le cas d'un dispositif de connexion pour conducteurs flexibles uniquement, la capacité de connexion assignée est la section du plus gros conducteur flexible à raccorder
[IEC 60998-1, ed. 2.0 (2002-12)]Тематики
- вывод, зажим электрический
- изделие электроустановочное
- клемма электротехническая
EN
FR
Русско-английский словарь нормативно-технической терминологии > номинальная способность к присоединению
-
6 включающая и отключающая способность при коротком замыкании
включающая и отключающая способность при коротком замыкании
-
[IEV number 442-05-48]EN
short-circuit (making and breaking) capacity
the alternating component of the prospective current, expressed by its rms value, which the circuit-breaker is designed to make, to carry for its opening time and to break under specified conditions
[IEV number 442-05-48]FR
pouvoir de coupure (et de fermeture) en court-circuit
composante alternative du courant présumé, exprimée en valeur efficace, que le disjoncteur, par conception, peut établir, peut supporter pendant son temps d'ouverture et peut interrompre dans des conditions spécifiées
[IEV number 442-05-48]EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > включающая и отключающая способность при коротком замыкании
-
7 предусмотрен
•Two pumps are provided, one of which supplies pressure fluid for operating the machine, and the other for operating auxiliary equipment.
•The Tornado aircraft has a high internal fuel capacity, both self-sealing bags and integral tanks being incorporated in the design.
•Provision is made for transverse movement of the lower die assembly.
•These factors of safety are built (or designed) into the set-up.
•The mill has provision for installation of a fifth stand.
Русско-английский научно-технический словарь переводчика > предусмотрен
-
8 обслуживание техническое
- technical maintenance
- servicing
- mechanical services
- maintenance works
- maintenance work
- maintenance support
- maintenance service
- maintenance
- machine servicing
- engineering service
- concept maintenance
- backup
техническое обслуживание
Совокупность действий, выполняемых для сохранения или восстановления состояния изделия, в котором оно способно отвечать требованиям соответствующих технических условий и выполнять необходимые функции.
[ ГОСТ Р МЭК 60050-426-2006]
техническое обслуживание
Текущие действия, выполняемые для сохранения в полной мере работоспособного состояния установленного электрооборудования.
[ ГОСТ Р МЭК 60050-426-2006]
техническое обслуживание
Комплекс операций и/или организационных действий, направленных на поддержание объекта в состоянии или возвращение объекта в состояние, в котором он способен выполнять требуемую функцию.
[ОСТ 45.152-99 ]
обслуживание техническое
Комплекс работ для поддержания исправности или работоспособности машин и оборудования при их эксплуатации, хранении и транспортировании
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
maintenance
1. All action taken to retain materiel in or to restore it to a specified condition. It includes: inspection, testing, servicing, classification as to serviceability, repair, rebuilding, and reclamation.
2. All supply and repair action taken to keep a force in condition to carry out its mission.
3. The routine recurring work required to keep a facility (plant, building, structure, ground facility, utility system, or other real property) in such condition that it may be continuously utilized, at its original or designed capacity and efficiency, for its intended purpose.[Dictionary of Military and Associated Terms. US Department of Defense 2005]Тематики
- тех. обсл. и ремонт средств электросвязи
Синонимы
- ТО
EN
- backup
- concept maintenance
- engineering service
- machine servicing
- maintenance
- maintenance service
- maintenance support
- maintenance work
- maintenance works
- mechanical services
- servicing
- technical maintenance
DE
FR
Русско-английский словарь нормативно-технической терминологии > обслуживание техническое
См. также в других словарях:
Capacity factor — The net capacity factor of a power plant is the ratio of the actual output of a power plant over a period of time and its output if it had operated at full nameplate capacity the entire time. To calculate the capacity factor, total the energy the … Wikipedia
capacity — system capacity The highest sustainable output from an operating system in units per given time. A system s overall capacity is determined by the capacity of its narrowest part, i. e. the bottleneck. For example, if a car assembly line can… … Big dictionary of business and management
New Bus for London — The New Bus for London (working title) The new Routemaster Design of the New Bus for London Manufacturer Wrightbus Capacity … Wikipedia
Doha bid for the 2016 Summer Olympics — Bids for the 2016 Summer Olympics Overview · Rio de Janeiro Madrid · Tokyo · Chicago 2016 Summer Olympics and Paralympics Details … Wikipedia
Hurricane preparedness for New Orleans — Hurricane preparedness in New Orleans has been an issue since the city s early settlement because of the city s location.New Orleans was built on a delta marsh. Unlike the first two centuries of its existence, today, a little less than half of… … Wikipedia
Interlochen Center for the Arts — is a privately owned, 1,200 acre (5 km²) arts education institution in Interlochen, Michigan, roughly 15 miles (24 km) southwest of Traverse City. Interlochen draws young people from around the world to participate in intensive… … Wikipedia
Air Command for Military Transportation — CATAM redirects here. For Computer Aided Teaching of All Mathematics, an optional component of the Mathematics course at Cambridge University, see Cambridge Mathematical Tripos. Air Command for Military Transportation, (English for Commando Aéreo … Wikipedia
Center for Biotechnology and Interdisciplinary Studies — The Center for Biotechnology and Interdisciplinary Studies is a new research facility at Rensselaer Polytechnic Institute (RPI). The convert|218000|sqft|m2|sing=on building is located on 15th street between RPI’s Playhouse and Academy Hall, next… … Wikipedia
International Foundation for Election Systems — IFES (formerly known as the International Foundation for Election Systems) is an international, non profit, Washington, DC based organization that supports the building of democratic societies . Founded in 1987, IFES has 200 employees with field… … Wikipedia
International Centre for Settlement of Investment Disputes — ICSID in force ICSID … Wikipedia
National Association for the Education of Young Children — (NAEYC) Founded 1926/1929 (Washington, DC) by Patty Smith Hill Headquarters Washington, DC Approximate Membership Nearly 80,000 … Wikipedia
Перевод: с русского на английский
с английского на русский- С английского на:
- Русский
- С русского на:
- Все языки
- Английский
- Немецкий
- Французский